| Technical Specifications |
| Supported Device Types |
Cisco, Nortel, 3COM, Juniper, Tasman
routers, switches, and firewalls; ND SatCom, iDirect
satellite routers, GPS devices; UNIX and Windows servers;
generic support for any console-managed device |
Supported Server OSs |
Windows 2003, Sun Solaris, Red Hat Linux, HP-UX, AIX |
| OOB Network Support |
Dial-in/PPP dial-out (with VPN support) via embedded,
Iridium and GlobalStar modems |
| SECURITY |
| Secure Remote Access |
Secure Shell (SSHv2); remote authentication and
accounting via TACACS and Radius; Telnet and direct-port
access optionally available: source address (IP and
Caller-ID) filtering; SHA-1 hashing of stored user
information |
| Flexible User Model |
Granular role-based authorization |
| Access and Activity Log |
Audit user access, device changes, and session activity
(with real-time, rules-based inspection) |
| Alerting |
| Syslog |
Forwards device console data and Envoy syslog messages
to syslog server |
| SMTP |
Sends alert messages using unique scheduling and
filtering system |
| SNMP |
Sends generated traps through the NRMS |
| SYSTEM |
| Network Interfaces |
Supports up to 32 network devices via serial (RS-232)
and up to 16 devices with additional auto-sensing
10/100 Base-T Ethernet interfaces |
| Management Interfaces |
Two 10/100 Base-T Ethernet interfaces and one RS-232
console port |
| On-board Storage |
NRM-4: 40GB; NRM-32: 80GB |
| Battery Backup |
Onboard battery provides approximately 30 minute
uptime |
| Peripheral Connectivity |
One RS232 power management port, one DB-9 modem
port (Optional V.92 RJ11), one AUX port using the
1-wire standard, and two USB 2.0 ports |
| DIMENSIONS & WEIGHT |
| Height and Width |
45 mm (1.75 in.) x 486 mm (17.1 in.); 1 rack unit
(1RU) |
| Depth and Weight |
NRM4 – 308 mm (12.125 in.) / 6.35 kg (14 lb.); NRM32
– 500 mm (17.5 in) /26 lb |
| OPERATING ENVIRONMENT |
| Power |
1A from 220VAC, 2A from 110VAC or 3A from 48VDC |
| Environmental Requirements |
0°C to 40°C / 5% to 95% relative humidity, non-condensing |
| REGULATION |
| Emissions |
FCC class A sub part B |
| Safety |
CSA USA safety standard |
| CE mark R & TTE directive |
This equipment has been marked with the CE mark.
This mark indicates compliance with EEC Directives
89/336/EC (electromagnetic compatibility), 73/23/EC
(low voltage), and 92/59/EC (general product safety).
A full copy of the Declaration of Conformity can be
obtained from Uplogix Inc., 823 Congress Ave., Austin,
Texas 78701, USA. |